タイミングよく RAID Volume から、error block の報告があったわけだが・・・
--
Feb 26 12:50:14 empress scsi: [ID 365881 kern.info] /pci@8,600000/LSILogic,sas@1 (mpt0):
Feb 26 12:50:14 empress Rev. 2 LSI, Inc. 1064 found.
Feb 26 12:50:14 empress scsi: [ID 365881 kern.info] /pci@8,600000/LSILogic,sas@1 (mpt0):
Feb 26 12:50:14 empress mpt0 supports power management.
Feb 26 12:50:14 empress scsi: [ID 365881 kern.info] /pci@8,600000/LSILogic,sas@1 (mpt0):
Feb 26 12:50:14 empress mpt0: IOC Operational.
Feb 26 12:50:25 empress scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/LSILogic,sas@1/sd@0,0 (sd0):
Feb 26 12:50:25 empress Error for Command: read Error Level: Retryable
Feb 26 12:50:25 empress scsi: [ID 107833 kern.notice] Requested Block: 1711136 Error Block: 1711136
Feb 26 12:50:25 empress scsi: [ID 107833 kern.notice] Vendor: LSILOGIC Serial Number: LSI Internal
Feb 26 12:50:25 empress scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Feb 26 12:50:25 empress scsi: [ID 107833 kern.notice] ASC: 0x29 (power on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x0
--
やっぱ、どのディスクでとか出ないね。
ディスク壊れても、どのディスクが壊れたか出なさそう。
まぁ、disk 壊れたら、raidctl の Disk Status で判断するしかないのかな。
--
# raidctl
RAID Volume RAID RAID Disk
Volume Type Status Disk Status
------------------------------------------------------
c2t0d0 IS OK c2t0d0 OK
c2t1d0 OK
c2t2d0 OK
--
ちなみに、上記の error block は、電源管理が絡んでいるっぽい。
なにげに mpt driver は、power management 対応。
デバイスが、省電力モードから復帰するときに、希に発生するみたい。